Watson-marlow 505U User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
15
313/314 (ml/min)
Flow rates
# 112 13 14 16 25 17 18
mm 0.5 0.8 1.6 3.2 4.8 6.4 8.0
" 1/50 1/32 1/16 1/8 3/16 1/4 5/16
313
55
1.7 3.9 14 55 121 198 275
220
6.6 15 57 220 485 790 1100
314
55
1.7 3.3 14 47 105 165 220
220
6.6 13 55 187 420 660 880
313
Maximum number of pumpheads
313/314 Peroxide/ Platinum Silicone
(0
bar
0.5) (0.5
bar
2.0)
# 112 13 14 16 25 17 18 112 13 14 16 25 17 18
mm 0.5 0.8 1.6 3.2 4.8 6.4 8.0 0.5 0.8 1.6 3.2 4.8 6.4 8.0
" 1/50 1/32 1/16 1/8 3/16 1/4 5/16 1/50 1/32 1/16 1/8 3/16 1/4 5/16
55
6 6 6 6 6 4 3 6 6 6 6 5 4 3
220
6 6 6 6 6 4 3 6 6 6 6 5 4 3
313/314 Marprene, Tygon, Neoprene, Fluorel
(0
bar
0.5) (0.5
bar
2.0)
# 112 13 14 16 25 17 18 112 13 14 16 25 17 18
mm 0.5 0.8 1.6 3.2 4.8 6.4 8.0 0.5 0.8 1.6 3.2 4.8 6.4 8.0
" 1/50 1/32 1/16 1/8 3/16 1/4 5/16 1/50 1/32 1/16 1/8 3/16 1/4 5/16
55
6 6 6 6 5 3 3 6 6 6 6 4 3 3
220
6 6 6 6 5 3 3 6 6 6 5 4 3 3
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19

Comments to this Manuals