Watson-marlow 520Du User Manual

Browse online or download User Manual for Pumps Watson-marlow 520Du. Watson-Marlow 520Du User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 107
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Watson-Marlow 520Du User Manual 1
WATSON-MARLOW BREDEL MANUALS
Watson-Marlow
520Du pumps
m-520du-gb-05
Contents
1 Declaration of conformity 3
2 Declaration of incorporation 3
3 Warranty 4
4 When you unpack your pump 5
5 Information for returning
pumps 6
6 Peristaltic pumps - an overview 7
7 Safety notes 8
8 Specifications 10
8.1 Dimensions 14
9 Good pump installation practice 15
9.1 General recommendations 15
9.2 Do’s and do not’s 15
10 Connecting to a power supply 17
11 Start-up check list 20
12 Switching on for the first time 20
13 Switching on subsequently 22
14 Manual operation 23
14.1 Keypad functions
in manual mode 23
14.2 Keypad lock 26
14.3 Keypad beep 26
14.4 Manual operation and
remote digital inputs
and outputs 26
15 Main menu 27
15.1 Keypad in menu screens 27
15.2 Main menu entry 28
16 PIN-secure process protection 29
17 Calibrate 30
18 Setup 34
18.1 Trim 35
18.2 Analogue 36
18.3 Display 40
18.4 Pump number 41
18.5 Baud 41
18.6 Stop bits 42
18.7 Xon/Xoff 42
18.8 Flow units 43
18.9 Run time 44
18.10 Outputs 45
18.11 Remote stop 47
18.12 Auto-restart 48
18.13 Set maximum speed 49
18.14 Backlight 50
18.15 ROM 50
18.16 Language 51
18.17 Defaults 51
18.18 Beep 52
18.19 Security code 52
18.20 Exit 54
19 MemoDose 55
19.1 Changing dosing speed 57
19.2 Footswitch operation
with MemoDose 57
20 Pin out details 58
21 Exit 59
22 Automatic control wiring 60
22.1 Speed: analogue input 1 63
22.2 Scaling: analogue input 2 64
22.3 Speed: analogue output 65
22.4 Tachometer frequency
output 65
22.5 Run / stop input 66
22.6 Direction input 67
22.7 Auto / manual toggle 67
22.8 MemoDose input 68
22.9 Leak detection input 68
22.10 Logic outputs 70
22.11 Supply voltages 73
23 Automatic control and operation 74
24 Network control and operation 77
24.1 RS232 command strings 79
25 Troubleshooting 80
25.1 Error codes 81
26 Drive maintenance 82
27 Drive spares 82
28 The 520R, 520R2 and 520RE
pumpheads 82
28.1 Pumphead fitting 83
29 520R, 520R2 and 520RE
installation 85
29.1 Opening the guard 85
29.2 520R and 520R2
tube loading 85
29.3 520RE: fitting the
drain port 87
29.4 520RE Element loading 87
29.5 520RE Element connection 90
30 520R, 520R2 and 520RE
maintenance 91
Page view 0
1 2 ... 107

Summary of Contents

Page 1 - Contents

Watson-Marlow 520Du User Manual 1WATSON-MARLOW BREDEL MANUALSWatson-Marlow 520Du pumpsm-520du-gb-05Contents1 Declaration of conformity 32 Declaration

Page 2

Watson-Marlow 520Du User Manual 108 Pump specificationsA nameplate is fixed to the rear of the pump. It contains manufacturer and contactdetails, prod

Page 3 - 1 Declaration of conformity

Watson-Marlow 520Du User Manual 100Marprene TL element, 0-2 bar (0-30psi), 200rpm, counter-clockwise rotationSta-Pure element, 0-2 bar (0-30psi), 200r

Page 4 - 3 Five year warranty

Watson-Marlow 520Du User Manual 101Marprene TH element, 4-7 bar (60-100psi), 200rpm, counter-clockwise rotation

Page 5 - 4 When you unpack your pump

Watson-Marlow 520Du User Manual 10234 Tubing and element part numbers1.6mm wall tubing for 520R pumpheadsmm inch # Marprene Bioprene Chem-Sure0.51/50

Page 6

Watson-Marlow 520Du User Manual 1032.4mm wall tubing for 520R2 pumpheadsmm inch # Marprene Bioprene Pumpsil0.51/50 913.A005.0240.81/32 913.A008.0241.6

Page 7 - Suitable applications

Watson-Marlow 520Du User Manual 1042.4mm wall elements for 520RE pumpheads0-2 bar (0-30 psi) pressure rated elementsIndustrialmm inch # Marprene TL Pu

Page 8 - 7 Safety notes

Watson-Marlow 520Du User Manual 10535 520 series pumping accessoriesAccessory Description Part codePump compatibility520ANCNetwork cable, RS232, with

Page 9

Watson-Marlow 520Du User Manual 10636 TrademarksWatson-Marlow, Bioprene, Pumpsil, LoadSure and Marprene are trademarksof Watson-Marlow Limited.Fluorel

Page 10 - 8 Pump specifications

Watson-Marlow 520Du User Manual 10739 Decontamination certificateIn compliance with the UK Health and Safety at Work Act and the Control ofSubstances

Page 11

Watson-Marlow 520Du User Manual 11IP NEMA 1st Digit 2nd Digit 3Protected againstingress of solid objectswith a diameter ofmore than 2.5mm.Tools, w

Page 12 - Pump specifications

Watson-Marlow 520Du User Manual 12Pump specificationsControl range (turndown ratio) 0.1-220rpm (2 200:1) Supply voltage/frequency100-120V/200-240V 50/

Page 13 - Standards

Watson-Marlow 520Du User Manual 13StandardsEC harmonisedstandardsSafety of machinery—electrical equipment of machines: BS EN 60204-1Safety requirement

Page 14 - 8.1 Dimensions

Watson-Marlow 520Du User Manual 148.1 DimensionsUnit weights520Du IP31 modelDrive only + 520R, 520R2+ 520REL,520REM, 520REH+ 505LIP319.70kg21lb 6oz10.

Page 15 - 9.2 Do’s and do not’s

Watson-Marlow 520Du User Manual 159 Good pump installation practice9.1 General recommendationsA correctly engineered installation will promote long tu

Page 16

Watson-Marlow 520Du User Manual 16Do keep delivery and suction tubes as short and direct as possible - though ideallynot shorter than 1m - and follow

Page 17 - 10 Connecting this product

Watson-Marlow 520Du User Manual 1710 Connecting this product to a power supplySet the voltage selector to 115V for 100-120V50/60Hz supplies or 230V fo

Page 18

Watson-Marlow 520Du User Manual 18If the mains power cable is inappropriate for your installation, it can be changed. Ensure that the pump is isolate

Page 19

Watson-Marlow 520Du User Manual 19Input line fusing: type T2,5A H 250V20mm time-delayed fuse, located in afuseholder in the centre of the switch-plate

Page 20 - 11 Start-up check list

Watson-Marlow 520Du User Manual 231 520R, 520R2 and 520RE rotor settings 9232 Pumphead spares 9333 Flow rates 9434 Tubing and element part numbers 102

Page 21

Watson-Marlow 520Du User Manual 2011 Start-up check listNote: See also 29.2 Tube loading. Ensure that proper connections are achieved between the pum

Page 22 - (if not in auto-restart mode)

Watson-Marlow 520Du User Manual 21First-time start-up defaultsLanguage Not set Analogue inputs 4-20mASpeed Maximum User trim NoneDirection Clockwise

Page 23 - 14 Manual operation

Watson-Marlow 520Du User Manual 2213 Switching the pump on in subsequent power cycles (if not in auto-restart mode) Switch on the power supply at the

Page 24

Watson-Marlow 520Du User Manual 2314 Manual operation14.1 Keypad functions in manual modeAll settings and functions of the pumpin manual mode are set

Page 25

Watson-Marlow 520Du User Manual 24 MAX: while pressed, MAX operates the pump at the maximum allowed speedand in the direction shown on the display. W

Page 26 - 14.3 Keypad beep

Watson-Marlow 520Du User Manual 25 DIRECTION: toggles the direction of rotation shown on the display. If thepump is then started by pressing the STAR

Page 27 - 15 Main menu

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 2614.2 Keypad lockThe keypad can be locked to prevent changes to pump speed or other settings, andmake i

Page 28 - 15.2 Main menu entry

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 2715 Main menu15.1 Keypad functions in menu screensIn addition to their functions in otheroperations, th

Page 29

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 2815.2 Main menu entryThe MENU key displays the main menu. It operates at any point in the pump’s activ-

Page 30 - 17 Calibrate

Watson-Marlow 520Du User Manual 2916 PIN-secure process protectionThe 520DuN and 520Du feature PIN-secure process protection. This allows thepump to b

Page 31 - Head and tube

Watson-Marlow 520Du User Manual 31 Declaration of conformityThis declaration was issued for Watson-Marlow 520Du pumps on February1, 2004. When this pu

Page 32 - Calibration dose

Watson-Marlow 520Du User Manual 3017 CalibrateThe pump can display flowrate in a choice of units as well as speed in revolutionsper minute. It must fi

Page 33

Watson-Marlow 520Du User Manual 31Head and tube If Head and tube is selected, the pump displays a list of standard pumpheadsthat can be fitted to the

Page 34 - 18 Setup

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 32Calibration dose The pump offers to run a calibration dose. Use the UP and DOWN keys tochoose Yes or

Page 35 - 18.1 Trim

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 33 Put a measuring container at the pump outlet. Press START. The pump runsfor 4 minutes, displaying an

Page 36 - 18.2 Analogue

Watson-Marlow 520Du User Manual 3418 SetupEntry to the Setup menu can be limited to users who correctly enter a three-digitsecurity code. If a securit

Page 37 - Input 1 - speed

Watson-Marlow 520Du User Manual 3518.1 TrimWhen the pump is under remote control, it tracks an analogue signal from the user’sremote control system to

Page 38

Watson-Marlow 520Du User Manual 36 The final press on ENTER ends the Analogue 1 trimming sequence. If Analogue 2 has been configured, the pump displ

Page 39 - Scaling - stroke

Watson-Marlow 520Du User Manual 37Input 1 - speed allows the user to tell the pump which signal type he will apply toAnalogue 1, or to choose the prog

Page 40 - 18.3 Display

Watson-Marlow 520Du User Manual 38Program Select Program using the UP or DOWN keys and press ENTER to confirm. The pump offers two choices: mA and V

Page 41 - 18.5 Baud

Watson-Marlow 520Du User Manual 39Scaling - stroke Select Scaling - stroke using the UP or DOWN keys and press ENTER toconfirm your choice. The pump

Page 42 - 18.7 Xon/Xoff

Watson-Marlow 520Du User Manual 43 Five year warranty520 cased pumps, 620 cased pumps and 720 cased pumpsFor any 520, 620 or 720 cased pump purchased

Page 43 - 18.8 Flow units

Watson-Marlow 520Du User Manual 4018.3 DisplayThe pump can display three default screens in manual mode: revolutions perminute, flowrate in a choice o

Page 44 - 18.9 Run time

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 4118.4 Pump numberThe 520Du pump can be individually controlled under RS232 as one of up to 16pumps. Fir

Page 45 - 18.10 Outputs

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 4218.6 Stop bitsThe 520Du pump can be set to communicate with control devices at a choice of stopbits se

Page 46

Watson-Marlow 520Du User Manual 4318.8 Flow unitsThe 520Du pump can display its flow rate in metric (SI) or US (imperial) units of vol-ume or mass. I

Page 47 - 18.11 Remote stop

Watson-Marlow 520Du User Manual 44 If you chose a volumetric flow rate from either screen, a confirmation screenappears briefly and the pump displays

Page 48 - 18.12 Auto-restart

Watson-Marlow 520Du User Manual 4518.10 OutputsThe 520Du pump offers four digital status outputs. See 12 Switching the pump onfor the first time for i

Page 49 - 18.13 Set maximum speed

Watson-Marlow 520Du User Manual 46 In the third screen of the Setup menu select Outputs using the UP andDOWN keys. Press ENTER to confirm your choice

Page 50 - 18.15 ROM

Watson-Marlow 520Du User Manual 4718.11 Remote stopThe 520Du pump can be started and stopped with a remote switch between pin 7and pin 19 using an ope

Page 51 - 18.17 Defaults

Watson-Marlow 520Du User Manual 48Alternatively ... To toggle the sense of the remote run / stop control between open=stop andopen=run: stop the pump

Page 52 - 18.19 Security code

Watson-Marlow 520Du User Manual 49Alternatively ... Stop the pump. Turn off the mains power switch at the rear of the pump. Hold down the START key

Page 53

Watson-Marlow 520Du User Manual 54 When you unpack your pumpUnpack all parts carefully, retaining the packaging until you are sure all componentsare p

Page 54 - 18.20 Exit

Watson-Marlow 520Du User Manual 5018.14 BacklightThe pump’s display can be illuminated or not according to choice. In the fourth screen of the Setup

Page 55 - 19 MemoDose

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 5118.16 LanguageThe pump can be set to operate in several languages. In the fifth screen of the Setup m

Page 56 - To repeat the dose

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 5218.18 BeepThe pump keypad can operate silently or indicate a positive key-press with a beepsound. In

Page 57 - MemoDose

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 53 In the fifth screen of the Setup menu select Security code using the UP andDOWN keys. Press ENTER to

Page 58 - 20 Pin out details

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 54 Repeat the digit-entry sequence. If the second three-digit code entered differs from the first, or

Page 59 - Alternatively

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 5519 MemoDoseEach time the pump is started by pressing START, it records the number of pump-head revolut

Page 60 - 22 Automatic control wiring

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 56To repeat the dose The pump has recorded the number of pumphead revolutions required to dis-pense the

Page 61 - RS232 control

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 5719.1 Changing dosing speedThe user must exit MemoDose in order to change pump speed (and direction). A

Page 62

Watson-Marlow 520Du User Manual 5820 Pin out detailsPin out detailsSelecting Pin out details causes the pump to display a warning screen and then itsp

Page 63 - 22.1 Speed: analogue input 1

Watson-Marlow 520Du User Manual 59Make a selection using the UP or DOWN keys and press ENTER to confirm yourchoice.The information on pinouts duplica

Page 64

Watson-Marlow 520Du User Manual 6StorageThis product has an extended shelf life. However, care should be taken after storageto ensure that all parts f

Page 65 - 22.3 Speed: analogue output

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 6022 Automatic control wiringInterfacing the pump with other devices is by means of three D-connectors a

Page 66 - 22.5 Run / stop input

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 61This pump passes all EMC compatibility requirements with up to 25m (82ft) of thecable type specified a

Page 67 - 22.6 Direction input

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 62Basic RS232 cablingNote: The CTS connection to pin 8 is optional, for use when error conditions arereq

Page 68 - 22.9 Leak detection input

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 6322.1 Speed: analogue input 1It is possible to control the speed of the pump remotely by one of these m

Page 69

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 6422.2 Scaling: analogue input 2It is possible to scale the speed of the pump remotely by one of these m

Page 70 - 22.10.1 Logic output 1

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 6522.3 Speed: analogue outputAn analogue output signal is available as a 0V-10V signal on pin 2 of the l

Page 71 - 22.10.2 Logic output 2

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 6622.5 Run / stop inputRemote run / stop: connect a remote switch between pins 7 and 19 of the lower D-c

Page 72 - 22.10.4 Logic output 4

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 6722.6 Direction inputTo enable remote direction control and disable the DIRECTION key on the keypad,lin

Page 73 - 22.11 Supply voltages

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 6822.8 MemoDose inputConnect a momentary contact switch such as a footswitch or a handswitch betweenpins

Page 74

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 69Connect the cable of a Watson-Marlow Tube monitor leak detector as follows:Note: Use only a Watson-Mar

Page 75

Watson-Marlow 520Du User Manual 76 Peristaltic pumps - an overviewPeristaltic pumps are the simplest possible pump, with no valves, seals or glands to

Page 76 - Emergency stop

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 7022.10.1 Logic output 1Output 1 is taken from pin 10 of the upper D-connector, depending on the logic s

Page 77

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 7122.10.2 Logic output 2Output 2 is taken from pin 11 of the upper D-connector, depending on the logic s

Page 78

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 7222.10.3 Logic output 3Output 3 is taken from pin 13 of the upper D-connector, depending on the logic s

Page 79

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 7322.11 Supply voltagesIn the table below, “Max load” is the maximum total load on each supply irrespec-

Page 80 - 25 Troubleshooting

Watson-Marlow 520Du User Manual 7423 Automatic control and operationCheck that the pump is ready to run before selecting automatic operation. Remoteco

Page 81 - 25.1 Error codes

 The pump is automatically switched into auto-restart mode and displays the !icon. The only keys active are STOP, AUTO/MAN, DIRECTION and START(avail

Page 82 - 28 The 520R, 520R2 and 520RE

Watson-Marlow 520Du User Manual 76Emergency stop In an emergency press the STOP key. The pump stops and displays an inter-ruption screen. If keypad

Page 83 - To reposition the track

Watson-Marlow 520Du User Manual 7724 Network control and operationCheck that the pump is ready to run before selecting network operation. Remotecontro

Page 84 - Rotor replacement

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 78How to get out of network operation Pressing the AUTO/MAN key displays three options: Analogue, Manua

Page 85 - 29 520R, 520R2 and 520RE

Watson-Marlow 520Du User Manual 7924.1 RS232 and RS485 command stringsCommand Parameters MeaningnCA - Clear LCD displaynCH - Home the cursornDOxxxxxxx

Page 86

Watson-Marlow 520Du User Manual 87 Safety notesIn the interests of safety, this pump and the tubing selected should only be used bycompetent, suitably

Page 87 - 29.4 520RE Element loading

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 8025 TroubleshootingIf the pump display remains blank when the pump is on, make the following checks: C

Page 88

Watson-Marlow 520Du User Manual 8125.1 Error codesIf an internal error occurs, a flashing error screen is displayed. Note: Signal out ofrange, Over si

Page 89

Watson-Marlow 520Du User Manual 8226 Drive maintenanceThere are no user serviceable parts inside the pump (except the powercable: see 10 Connecting th

Page 90 - 29.5 520RE Element connection

Watson-Marlow 520Du User Manual 8328.1 Pumphead position, removal andreplacementThe pumphead track can be fitted in one of three orientations to provi

Page 91 - 30 520R, 520R2 and 520RE

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 84Rotor removal Remove any tubing from the pumphead. Open the flexible rotor cap in the centre of the

Page 92

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 8529 520R, 520R2 and 520REinstallation29.1 Opening the pumphead guard Unlock the pumphead guard by turn

Page 93 - 32 Pumphead spares

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 86 Mark a 225mm (8 7⁄8 in) length onto the section of the tubing which is to belocated into the pumphea

Page 94 - 33 Flow rates

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 8729.3 520RE: fitting the drain portThe drain port is an optional extra, supplied with the pumphead. It

Page 95

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 88Note: To achieve 4 bar and 7 bar pressures using a 520RE pump and the appropri-ate rotor and element,

Page 96 - Continuous tubing

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 89520RE element loading procedureNote: The element loading procedure is the same for industrial (picture

Page 97 - Elements

Watson-Marlow 520Du User Manual 9There are moving parts inside the pumphead. Before opening the tool-unlockable pumphead guard, ensure that the follow

Page 98 - Performance curves

Watson-Marlow 520DuN IP66/NEMA 4X User Manual 9029.5 520RE Element connectionSelect suitable tubing to connect to the tubing element supply and discha

Page 99

Watson-Marlow 520Du User Manual 9130 520R, 520R2 and 520REmaintenance As part of regular cleaning and maintenance (and at least every three months),l

Page 100

Watson-Marlow 520Du User Manual 92General guide to cleaning with solvents31 520R, 520R2 and 520RE rotorsettings520R, 520R2 and 520RE pumpheads are fac

Page 101

Watson-Marlow 520Du User Manual 9332 Pumphead sparesParts may be ordered individually.053.1011.100 520R053.1011.2L0 520R2053.1011.EL0 520REL053.1011.E

Page 102

Watson-Marlow 520Du User Manual 9433 Flow ratesPumping conditionsFor precise and repeatable performance it is important to determine flowrates under o

Page 103

Watson-Marlow 520Du User Manual 95520REPerformance figures for the 520REL and 520REM have been recorded against 2barpeak pressure and 4bar peak pressu

Page 104

Watson-Marlow 520Du User Manual 96520R Fluorel (ml/min)Speedrange1.6mm 3.2mm 4.8mm 6.4mm 8.0mm520Du/R, 520Du/R20.1-220rpm0.03-700.13-2800.29-6300.51-1

Page 105

Watson-Marlow 520Du User Manual 97Elements520REL Neoprene, Sta-Pure, Chem-Sure, Pumpsil(ml/min)520REL Marprene / Bioprene TL (ml/min)Speedrange3.2mm 6

Page 106 - 38 Publication history

Watson-Marlow 520Du User Manual 98Performance curvesMarprene continuous tubing, 1.6mm wall, 200rpm, clockwise rotationMarprene continuous tubing, 1.6m

Page 107

Watson-Marlow 520Du User Manual 99Marprene continuous tubing, 2.4mm wall, 200rpm, clockwise rotationMarprene continuous tubing, 2.4mm wall, 200rpm, co

Related models: 520DuS | 520US | 520SN | 520S | 520U | 520BpN | 520Bp | 520UN |

Comments to this Manuals

No comments