Watson-marlow 120F/DV User Manual

Browse online or download User Manual for Pumps Watson-marlow 120F/DV. Watson-Marlow 120F/DV User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Contents

Watson-Marlow 120 IP31 pumps 1WATSON-MARLOW MANUALSWatson-Marlow 120 cased pumps120F/DVm-120coversheet-F-114DV-gb-01 Original instructionsContents1 Ge

Page 2

Watson-Marlow 120 IP31 pumps: general information 8ValvesPeristaltic pumps are self-priming and self-sealingagainst backflow. No valves are required i

Page 3

Watson-Marlow 120 IP31 pumps: general information 91.9 Power supplyThe 120 pump is suitable for single-phase mainselectricity supplies only via the do

Page 4 - Conditions

Watson-Marlow 120 IP31 pumps: general information 10Unit weightsDriveonly+114DV+ 102R+ 400D1+ 400DM2+400DM31.4kg 1.5kg 1.55kg 1.65kg 1.7kg 1.7kg1.10 D

Page 5 - 1.5 Information for

Watson-Marlow 120 IP31 pumps: general information 111.11 Start-up checklistNote: See also section 2 (120F, 120S or 120Udrives) and section 3 (102R, 11

Page 6 - 1.6 Peristaltic pumps

Watson-Marlow 120 IP31 pumps: general information 121.14 DecontaminationcertificateIn compliance with the UK Health and Safety atWork Act and the Cont

Page 7 - 1.7 Safety notes and

Watson-Marlow 120F IP31 pumps: operating instructions 1WATSON-MARLOW MANUALSWatson-Marlow 120F cased pumps:Section 2 of 3: Operating manualm-120F-ip31

Page 8 - Power supply standards

Watson-Marlow 120F IP31 pumps: operating instructions 2120F Start-up defaultsSpeed Fixed: see keypadDirection Fixed: clockwiseBeeper Fixed: onAuto-sta

Page 9 - 1.8 Good pump

Watson-Marlow 120F IP31 pumps: operating instructions 32.4 Operation2.4.1 Start and stopTo start the pump, press the green START key onthe keypad. The

Page 10 - 1.8.2 Do’s and do not’s

Watson-Marlow 120F IP31 pumps: operating instructions 42.7 TroubleshootingIf the pump fails to operate, make the followingchecks: Check that the dedi

Page 11 - 1.9 Power supply

Watson-Marlow 114DV pumphead: operating instructions 1WATSON-MARLOW MANUALSWatson-Marlow 120 cased pumpsSection 3 of 3: 114DV pumpheadsm-114pumphead f

Page 13 - 1.13 Drive spares

Watson-Marlow 114DV pumphead: operating instructions 23.1 PumpheadspecificationsThe 114DV pumphead has four rollers and accepts1.6mm wall thickness tu

Page 14 - 1.14 Decontamination

Watson-Marlow 114DV pumphead: operating instructions 33.3 114DV pumpingconditions: pressureand viscosity All pressure values in this operating instru

Page 15 - 2.1 Pump specifications

Watson-Marlow 114DV pumphead: operating instructions 43.5 Tube holderpositioningThe pumphead can be adjusted to accommodate1.6mm wall tubing in sizes

Page 16 - 2.3 Switching the

Watson-Marlow 114DV pumphead: operating instructions 5To change from the largetube to the small tube setting Press down and slightly away from the fr

Page 17 - 2.6 Error codes

Watson-Marlow 114DV pumphead: operating instructions 63.6 Tube loading andremoval Lift the flip top until fully open. Select enough tube length for

Page 18 - 2.7 Troubleshooting

Watson-Marlow 114DV pumphead: operating instructions 73.8 114DVPerformance dataFlow rates are normalised test values obtainedusing new tubing with the

Page 19

Watson-Marlow 114DV pumphead: operating instructions 83.9 114DV continuoustubing product codes1.6mm wall thickness tubing for the114DV pumpheadmm # Ma

Page 20 - 3.2 114DV safety

Watson-Marlow 120 IP31 pumps: general information 1WATSON-MARLOW MANUALSWatson-Marlow 120 cased pumpsSection 1 of 3: general informationm-120general-g

Page 21 - 3.4 114DV pumphead

Watson-Marlow 120 IP31 pumps: general information 21.1 Declaration ofconformityThis declaration was issued for Watson-Marlow 120 pumps on April 28, 20

Page 22 - 3.5 Tube holder

Watson-Marlow 120 IP31 pumps: general information 3Exceptions The warranty shall not apply to repairs or service necessitated by normal wear and tear

Page 23 - 3.5.1 Tube holder

Watson-Marlow 120 IP31 pumps: general information 41.6 Peristaltic pumps -an overviewPeristaltic pumps are the simplest possible pump,with no valves,

Page 24 - 3.7 114DV pumphead

Watson-Marlow 120 IP31 pumps: general information 5This symbol, used on thepump and in this manual,means: Caution, refer toaccompanying documents.This

Page 25 - Performance data

Watson-Marlow 120 IP31 pumps: general information 6If hazardous fluids are to be pumped, safety proce-dures specific to the particular fluid and appli

Page 26 - 114DV pumphead

Watson-Marlow 120 IP31 pumps: general information 7Power supply specificationsInsulation category Class II: double insulated, no earthMains voltage/f

Related models: 120F | 120R | 120S/R | 120U/D1 | 120U/DM2 | 120U/DM3 |

Comments to this Manuals