WATSON-MARLOW BREDEL E-MANUALS
PB0230GB02
Watson-Marlow 701 baseplate
p
um
p
s
Contents
1. Declaration of conformity
2. Declaration of incorporation
3. Warranty
4. Information for returning pumps
5. Safety
6. Recommended operating
procedures
7. Installation
8. Troubleshooting
9. AC Motor maintenance
10. Gearbox maintenance
11. 701PB air motors
12. 701PB air motors:
troubleshooting
13. Pump specification
14. 701RB pumphead: key safety
information
15. 701R safe-guarding
16. 701RB, 701RBX, 701RBG, 701RBE, 701RBEX
Pump installation
17. Tube loading
18. Fitting an extension pumphead
19. Pumphead spares: continuous tubing
20. Pumphead spares: tubing elements
21. Pumphead spares: rotor
22. Flow rates
23. 701RB, 701RBX, 701RBG, 701RBE, 701RBEX
product codes
24. Flow, pressure and suction
25. Maximum peak working pressure ratings
26. Outline dimensions
27. Trademarks and disclaimer
28. Warning not to use pumps in patient-connected
applications
29. Decontamination certificate
Pa
g
e 1 of 25Watson-Marlow Bredel E-Manuals
14/12/2009file://M:\sta
g
in
g
\
p
dfs-
g
lobal\m-701base
p
late-
g
b-02.htm
Page view 0
1 2 3 4 5 6 ... 24 25

Summary of Contents

Page 1 - PB0230GB02

WATSON-MARLOW BREDEL E-MANUALS PB0230GB02 Watson-Marlow 701 baseplate pumps Contents 1. Declaration of conformity 2. Declaration of incorpora

Page 2

Replacing the V-belt  Unscrew the socket head screws and remove the cover with the entire speed control mechanism.  Remove the V-belt.  Wrap the

Page 3 - 1 Declaration of conformity

Lubrication Use a detergent SAE#10 automotive engine oil. Lubrication is necessary for all moving parts and rust prevention. We recommend that an auto

Page 4

13 Pump specification 14 701RB Pumphead: key safety information  Ensure that the pump is isolated from mains voltage.  Ensure that there is no pres

Page 5

16 701RB, 701RBX, 701RBG, 701RBE, 701RBEX Pump installation A correctly engineered installation will promote the best possible tube life, so please en

Page 6 - 5 Safety

17 Tube loading 701 baseplate pumps can be operated with a 701RB continuous tubing pumphead or with a 701RBE pumphead fitted with Watson-Marlow LoadSu

Page 7

 Fit the delivery clamp loosely to allow any excess tubing to work its way through the pumphead. (See Re-tensioning the tubing, below)  Position th

Page 8 - 7 Installation

701RBE and 701RBEX LoadSure tube element loading 700 series LoadSure tube elements:  remove the chance of premature tube failure caused by incorrec

Page 9 - 10 Gearbox maintenance

 Position the left-hand end of the track so that the track-securing bolt can be inserted.  Tighten the track-securing bolt with the 6mm Allen key p

Page 10 - 11 701PB Air motors

19 Pumphead spares: continuous tubing Models 701RB, 701RBX, 701RBG1 MRA0027A Pivot pin assembly 1 MRA0034A Pivot pin assembly ~701RX 2 MRA0021A Roto

Page 11

20 Pumphead spares: tubing elements 21 Pumphead spares: rotor Models 701RBE, 701RBEX1 MRA0027A Pivot pin assembly 1 MRA0034A Pivot pin assembly ~701RX

Page 12 - 15 701R Safe-guarding

Page 2 of 25Watson-Marlow Bredel E-Manuals14/12/2009file://M:\staging\pdfs-global\m-701baseplate-gb-02.htm

Page 13 - Pump installation

22 Flow rates Flow rates were obtained using silicone tubing with the pumphead rotating clockwise, pumping water at 20°C with zero suction and deliver

Page 14 - 17 Tube loadin

23 701RB, 701RBX, 701RBG, 701RBE, 701RBEX product codes mm inch # Marprene Marprene LoadSure Bioprene Platinum silicone 9.6 3/8 193 902.0096.048

Page 15

24 Flow, pressure and suction 25 Maximum peak working pressure ratings 701RB 701RBX 701RBG 701RBE 701RBEX 2bar 2bar 4bar 2bar 2bar Page 22 of 2

Page 16

26 Outline dimensions Page 23 of 25Watson-Marlow Bredel E-Manuals14/12/2009file://M:\staging\pdfs-global\m-701baseplate-gb-02.htm

Page 17 - 18 Fitting an extension

27 Trademarks and disclaimer Watson-Marlow, Bioprene, LoadSure and Marprene are trademarks of Watson-Marlow Limited. Fluorel is a trademark of 3M. S

Page 18

29 Decontamination certificate In compliance with the UK Health and Safety at Work Act and the Control of Substances Hazardous to Health Regulations,

Page 19 - elements

1 Declaration of conformity When this pump unit is used as a stand alone pump it complies with: Machinery Directive 2006/42/EC, EMC Directive 2004/108

Page 20 - 22 Flow rates

2 Declaration of incorporation When this pump unit is to be installed into a machine or is to be assembled with other machines for installations, it m

Page 21

3 One year warranty - 701PB/R Watson-Marlow Limited warrants, subject to the conditions below, through either Watson-Marlow Limited, its subsidiaries,

Page 22 - 24 Flow, pressure and suction

5 Safety In the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained personnel after they have re

Page 23 - 26 Outline dimensions

6 Recommended operating procedures On variable speed models please note that the mechanical speed variator must not be adjusted when the motor is not

Page 24 - 27 Trademarks and disclaimer

7 Installation Pump Site the pump on a flat, horizontal, vibration-proof surface allowing a free flow of air around it. Ensure there is 1m of relativ

Page 25 -  

8 Troubleshooting Should the pump fail to operate, make the following checks to determine whether or not servicing is required.  Check the mains sup

Comments to this Manuals