7 Installation
Pump
Site the pump on a flat, horizontal, vibration-proof surface allowing a free flow of air around
it. Ensure there is 1m of relatively straight flexible tubing before the pumphead inlet and
after the pumphead outlets. Two 15mm-diameter holes are provided for bolting the
baseplate to the mounting surface, if required.
AC Motor
Ensure that mains voltage/frequency are in accordance with motor nameplate
information.
Secure protective conductor connections.
If a three-phase motor is running in the wrong direction, interchange any two phases.
Close unused cable entrance holes and the terminal box itself in a dust and watertight
manner.
A current overload relay should be fitted to a contact breaker. Connect the motor in
accordance with the wiring diagram that is in the motor terminal box.
When a thermal protection switch is fitted in the motor, the leads will be found in the
motor terminal box. They should be connected to stop the pump if the switch operates.
The switch will open circuit at an over temperature condition. See below for the
connection of the drive motor showing possible ancillary switches and protections.
The ancillary switches are rated to 220/240V 1ph 50Hz. The Start contact should
have a sprung return which will disengage following energisation of the coils C1
and C1/1.
1. Emergency
stop
2. Start
3. Stop
Ensure that an emergency stop switch is fitted within reach of the pump.
The 701R pumphead range has electrostatic earth straps which are
connected to the baseplate. Please ensure that the baseplate is
electrostatically earthed to ground before operation.