505Di505di-gb-03.pdf
10Fit the other end of the tubing into the second spring loaded clamp, ensuring that the tubing is not slack in thepumphead, since this can reduce tub
11Pumphead sparesNumber Spare Description1 MN 1200M Lockable guard2 FN 4502 Lock3 FN 2341 Hinge screw4 MN 0266M Hinge grey5 MNA0623A Tube clamp assemb
12505L pumpheadThe twin offset track design of the 505L utilises 2.4mm wall double-y tube elements to overcome pulsation for accuratedosing and dispen
13Tube loadingDouble-y elementLift the track locating levers and remove track. Locate one end of double-y element over one of the 505L clamping pegs.S
14505L Care and maintenanceCheck all moving parts for freedom of movement occasionally. If aggressive fluids are split onto the pumphead, removefrom d
15Drive spares564398710 11 12131564398710 11 12131Number Spare Description1 SW 0147 On/off switch2 FS 0003 Fuse3 TF0031 Transformer4 MN0565B Switch pa
16Outline dimensions505Di/RL505Di/L
17English User decision Pump screen display Terminal Operation Flow connector ManualinputAStop Start EnterStepMain MenuCW CCWEnglish Instructionrefere
18DoseSet dose volume or weight ml/gSet dosing interval (s)Set new programEnter rpm/ volume/ directionProceed with dose program calledDosing interval
19English* Volume dosing using 501RL, 1.6mm bore tubing. Pumphead/tubing selection screens vary according to selectionrequired.A. Switch on power to
2DeclarationsDeclaration ofconformityWhen this pump unit is used as a stand alone pump it complies with: Machinery Directive98/37/EC EN60204-1, Low Vo
20Record ProgramProceed to dose Record programProg a b c d e f g h i j k l mProg n o p q r s t u v w x y z Proceed to dose Record programRecord progr
21EnglishQ. User decision to record a set of dose program settingsR. Select the memory location. Large letter denotes a previously stored program. S
22Recall ProgramRecall programProg A b c d e f g h i j k l mSet new program Recall program Prog N o p q r s t u v w x y z Set new program Recall prog
23EnglishX. Recall previously set program from memoryY. Select required programZ. Verification of selected dose programA.1 Verification of interva
24Pumphead ml/rev RecalibrateCalibration dose Head and Tubing###rpm cw/ccw press startWait or press Stop when readyPress Stop when ready####.#ml #
25EnglishD1. Indication of previous calibration (if completed)E1. Decision to calibrate pump to new pumphead and tubing sizeF1. Select the pumphead
26StartDose Cal Manual Network SetupSet new programRecall programProg A b c d e f g h i j k l m#.###ml #.###g Enter DoseDoseSet new program Recall p
27EnglishN1. Switch on pump and Main menu is calledO1. User chooses dose optionP1. Recall program option available only if program has previously b
282###rpm ####ml/min CW/CCW Press enter Proceed to dose Record programProceed to doseUnstored program ####ml ##doseProg a b c d e f g h i j k l mPro
29EnglishA2. Set drive speed (limited by pumphead fitted)B2. Set volume flow rateC2. Set direction of rotation of driveD2. Proceed to dose or save
3 DO run at a slow speed when pumping viscous fluids. When using the 501RL pumphead, a 4.8 or 6.4mm bore tube witha 1.6mm wall will give best results
30Stored program (A-Z) ####ml ##dose6##sec interval ###rpm ####ml ##dose Press Start7Pump starts dosing Restart dosing Recalibrate ExitRestart dosing
31EnglishN2. Dose program called for useO2. Indication of dosing time interval and pump speedP2. Volume/weight set and number of doses. Press start
324Stored program (A-Z) ####ml ##dose##sec interval ###rpm Accept program Next program Delete program? Yes NoNoYes5Program is deleted69AcceptNextAcce
33EnglishI3. Indication of volume/weight dosed and number of doses remainingJ3. Indication of volume/weight dosed and number of doses/hourK3. Optio
34Symbols#English Tube number Tube bore Double-Y Maximum cassettes rpmEnglish Pressure (+) Suction Clockwise (rpm) Anticlockwise (rpm) Stop501RL, 501R
35313/314 (ml/min)Flow rates # 112 13 14 16 25 17 18mm 0.5 0.8 1.6 3.2 4.8 6.4 8.0" 1/50 1/32 1/16 1/8 3/16 1/4 5/16313 220 6.6 15 60 55 121 198
36501RL, 501RLG, 313Product codesmm " # Peroxide Silicone Platinum Silicone Marprene Bioprene 0.5 1/50 112 910.0005.016 913.0005.016 902.0005.016
37505L, 505LG(2.4mm) Product codesmm "# PeroxideSiliconePlatinumSiliconeMarprene STA-PURE Gorefluoroelastomer1.6 1/16 119 910.E016.024 913.E016.
38Watson-Marlow, Bioprene and Marprene are trademarks of Watson-Marlow Limited.Tygon is a trademark of the Saint Gobain Performance Plastics Company.S
39Product use and decontamination declarationIn compliance with the UK Health & Safety at Work Act and the Control of Substances Hazardous to Heal
4• Check the voltage selector switch is in the correct position.• Check the fuse in the mains socket.• Check that the pump is not stalled by incorr
5• Change direction by pressing the CW/CCW key. Indication of direction of rotation is provided via the LCD display.• Select the maximum speed : p
6nZY Show status if pump n STARTed 1 or STOPped 0nTC Clear tachometer counternRT Read tachometer counterFor writing to pump number n displaynCA Clear
7A AnticlockwiseC Clockwisessss Four character speed field in tenths of an rpm in the range of 0001 to 2200 with leading and trailing zeros to form af
8If the motor is dosing, it has no effect until the next dose. Typically four further doses are required to achieve maximumdose accuracy. Then the pum
9Care and maintenanceThe only scheduled maintenance required on the 505Di is to inspect the motor brushes and to replace them before theirlength is le